NHTSA : 14V532000🔴 ⚠️ Alta gravidade

Detalhes da Campanha

Componente: SERVICE BRAKES, AIR

Descrição da Falha

New Flyer Industries Ltd. (New Flyer) is recalling certain model year 2013 XD35, XDE35, XE40, and 2013-2014 XD40, XD60, XDE40, XDE60, XN35, XN40, and XN60 transit buses. During installation, the Brake Pedal Mounting Plate may have been clamped between the Brake Pedal Assembly and the Brake Valve Actuator (BVA) resulting in a misalignment and binding of the internal piston in the BVA.

Consequência / Perigo

The binding of the piston may result in increased resistance while applying the brakes and the potential for brake drag once the brake pedal is released. These conditions increase the risk of a crash.

Solução Proposta

New Flyer will notify owners and will replace the brake pedal mounting plate and the Brake Valve Actuator (BVA), free of charge. The recall began on September 15, 2014. Owners may contact New Flyer customer service at 1-204-934-4876. New Flyer's number for this recall is R14-019.

🚗 Veículos Afetados17

Todos os modelos abaixo foram chamados a revisão para este exato mesmo problema.