Recall NHTSA 18V553000: Altec Aerial Device 2017–2018 (electrical system)
Altec Aerial Device 2017–2018 were recalled in the United States on August 22, 2018, with 40 units affected over a defect in electrical system (risk: an electrical short can increase the risk of a fire); the repair is free of charge.
- Agency
- National Highway Traffic Safety Administration (NHTSA) (United States)
- Date
- Component
- Electrical and lighting
- Risk
- An electrical short can increase the risk of a fire.
- Remedy
- Altec will notify owners, and dealers will inspect the battery fuse location, relocating it if necessary, free of charge. The recall is expected to begin October 15, 2018. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 691.
- Units affected
- 40
- Official source
- See the original notice
What is the defect?
Altec Industries Inc. (Altec) is recalling certain 2017-2018 Altec LS63 Aerial Devices. The fuse for the battery was not installed to the guidelines. The incorrectly placed fuse may increase the risk for an electrical short.