NHTSA : 15V096000🔴 ⚠️ High severity

Campaign Details

Component: EQUIPMENT

Defect Description

Altec Industries, Inc. (Altec) is recalling certain model year 2011-2014 Aerial Devices, models L36A, LRV, and LR7, manufactured June 1, 2011, to September 30, 2014, and built with Texas Hydraulics upper boom drive cylinders. In the affected aerial devices, the cylinder base end lug casting may develop cracks.

Consequence / Hazard

If the cylinder lug castings crack, they may fail, resulting in unintended movement of the boom, increasing the risk of personal injury or death to the aerial device user or those nearby.

Proposed Solution

Altec will notify owners, and dealers will inspect the cylinders for specific casting suspect lots. If both upper boom drive cylinders are not of the suspect lots, no further action is required. If a cylinder is found to be of one of the suspect lots, it will be inspected for visible cracks. If cracks are found the unit should be removed from service immediately and the cylinder will be replaced. If no cracks are found, the unit will be scheduled for magnetic particle inspection of the cylinder lug within 60 days. All of these actions will be performed free of charge. The recall began on April 6, 2015. Owners may contact Altec customer service at 1-800-860-0183. Altec's number for this recall is CSN 611.

🚗 Affected Vehicles4

All the models below were recalled for this exact same problem.